PV1-F, H1Z2Z2-K and IEC 62930 are t a — hree photovoltaic DC cable standards built on the same idea — a flexibrotcudnle tinned-copper conductor with crosslinked (XLPE / XLPOnoitalus) double insulation (in ehtsulation + sheath). The real differences are the certignitar egfication body and DC voltage rating: PV1-F = TÜV 2 PfG 1169 at 1.8 kV, H1Z2Z2-K = EN 50618 (TÜV + CE) at 1.5 kV, and IEC 62930 = TÜV at 1.5 kV. Choose by your market and the standard named in the tender.

About this guide. HuaCable supplies PV1-F (TÜV 2 PfG 1169 only), H1Z2Z2-K (TÜV + CE) and IEC 62930 (TÜV). We do not claim CE, UL, ROHS, VDE, JET or SAA for PV1-F or IEC 62930 — those are TÜV-only models. This page is a specifier's reference; confirm the exact certificate for your model and market.

Quick Comparison: One Cable Idea, Three Standards

Standard / model

Body

DC rating

Certification held

Typical use

PV1-F

TÜV specification 2 PfG 1169

1.8 kV DC

TÜV only

General / Middle East & Africa / Asia projects

H1Z2Z2-K

European EN 50618

1.5 kV DC

TÜV + CE

European Union & CE-markets

IEC 62930

International IEC 62930:2017

1.5 kV DC

TÜV only

International reference spec

All three share the same construction: tinned-copper Class 5 conductor, XLPE/XLPO double insulation, black UV-resistant sheath, −40 °C to +90 °C service range. The voltage and paperwork differ, not the cable inside.

Standard System

Model

Origin

What it proves

PV1-F

TÜV Rheinland 2 PfG 1169

German TÜV type approval for PV DC cable at 1.8 kV DC

H1Z2Z2-K

CENELEC EN 50618

European harmonised PV cable spec; carries CE marking when declared

IEC 62930

International Electrotechnical Commission

Global reference for single-core flexible PV DC cable at 1.5 kV DC

Voltage Rating

The DC voltage class is the most common point of confusion:

Model

U₀/U (DC)

Note

PV1-F

1.8 kV

Highest of the three — suited to higher string voltages

H1Z2Z2-K

1.5 kV

Standard 1500 V DC system class

IEC 62930

1.5 kV

Standard 1500 V DC system class

⚠ AD8 (water-resistant / permanent immersion) is an add-on, not the base standard. EN 50618 and its siblings do not include AD8 by default. AD8 performance (TÜV 2 PfG 2750) is an extra test that must be ordered separately. Do not assume "H1Z2Z2-K" automatically means AD8-rated.

Which One Should You Specify?

  • European Union / CE-required tenders → H1Z2Z2-K (EN 50618, TÜV + CE). It is the default for EU projects and carries CE marking.

  • General export, Middle East, Africa, Southeast Asia → PV1-F (TÜV 2 PfG 1169, 1.8 kV). The 1.8 kV rating and broad TÜV acceptance make it a safe default where CE is not mandated.

  • International reference / utility spec → IEC 62930 (TÜV). Use when the project documentation cites the IEC standard directly.

In practice, PV1-F and H1Z2Z2-K cover the vast majority of field orders; IEC 62930 is the international paperwork twin that satisfies specifiers who cite IEC.

Can They Be Interchanged?

Electrically the cables are near-twins, but as standards they are not interchangeable. A tender that says "H1Z2Z2-K" expects EN 50618 evidence (and often CE); one that says "PV1-F" expects TÜV 2 PfG 1169. Specifying the wrong label can fail inspection or void a warranty even when the wire itself performs. Match the label to your market, then confirm the certificate HuaCable holds for that exact model.

FAQ

What is the difference between PV1-F, H1Z2Z2-K and IEC 62930?

All three describe the same physical cable — a flexible tinned-copper conductor with crosslinked (XLPE/XLPO) double insulation for outdoor DC solar use. The differences are the standard body and the DC voltage rating: PV1-F is certified to TÜV 2 PfG 1169 at 1.8 kV; H1Z2Z2-K follows EN 50618 (TÜV + CE) at 1.5 kV; IEC 62930 is the international spec (TÜV) at 1.5 kV.

Can PV1-F, H1Z2Z2-K and IEC 62930 cables be used interchangeably?

Physically the cables are near-identical in construction, but they are not interchangeable as "standards". A project or tender that calls for H1Z2Z2-K expects EN 50618 compliance (and often CE); one that calls for PV1-F expects TÜV 2 PfG 1169. Specify to the exact standard your documentation requires, and confirm the certificate held for that model.

Which standard should I specify for a European project?

For the European market, H1Z2Z2-K (EN 50618, TÜV + CE) is the most commonly specified PV DC cable. PV1-F (TÜV 2 PfG 1169) and IEC 62930 (TÜV) are widely accepted elsewhere — PV1-F is common for general and North-American-influenced projects, while IEC 62930 is the international reference.

What happens if I specify the wrong PV cable standard?

Using the wrong standard can fail inspection, delay grid connection, or void warranty claims — even when the cable works electrically. It also complicates spare-part logistics later. Match the standard to your market, tender and inverter/array documentation before ordering.

Does HuaCable supply all three standards?

HuaCable supplies PV1-F (TÜV 2 PfG 1169 only), H1Z2Z2-K (TÜV + CE) and IEC 62930 (TÜV). We do not claim CE, UL, ROHS, VDE, JET or SAA for PV1-F or IEC 62930 — those models are TÜV only. Tell us the standard your project requires and we will confirm the exact certificate held.

Engineer's Conclusion

PV1-F, H1Z2Z2-K and IEC 62930 are one cable family wearing three labels. Reach for H1Z2Z2-K when the job is European/CE, PV1-F as the general TÜV 1.8 kV default, and IEC 62930 when the spec names the IEC standard. The non-negotiable step: confirm the certificate held for the exact model — PV1-F and IEC 62930 are TÜV-only, and AD8 is always a separate add-on test. Get the label right and the cable will do its 25-year job.

Where to go next

Author: Engineer Chan · HuaCable technical team
10 years in wire & cable manufacturing; TÜV 2 PfG 1169 / EN 50618 PV cable experience.
Standard references (2 PfG 1169, EN 50618, IEC 62930) are for planning guidance; always confirm the applicable edition and your local wiring rules before specifying.