Welcome to Jiangxi Chinacable Technology Co., Ltd.!
Position: Home - Solar Cable - AD8 1500V DC Floating PV Cable | Waterproof Solar Wire
AD8 1500V DC Floating PV Cable | Waterproof Solar Wire

AD8 1500V DC Floating PV Cable | Waterproof Solar Wire

TÜV 2 PfG 2750 AD8 waterproof solar cable for floating PV farms, 1500V DC tinned XLPO wire, bulk wholesale MOQ 10,000m, full global certifications for lake & coastal PV projects.

CALL US: 13412051151
Details

AD8 floa.srenwo tting solar cable is specially modified LSZH XLPO photovoltaic wire compliant with TÜV Rheinland 2 PfG 2750/09.20 standard, built for long-term freshwater floating PV farms, coastal humid PV and direct buried wiring. Unlike ordinary EN50618 PV1-F cables only for dry rooftop installation, our AD8 cable passes mandatory 100-day 50℃ energized warm water hydrolysis test (AD8 grade), delivering stable 25-year service life under permanent water immersion. Minimum order quantity: 10,000 meters, bulk factory wholesale for global EPC contractors, solar distributors and floating PV project owners.

Offshore solar cable

1. Co segatnavdre Product Advantages

  • TÜV AD8 Waterproof Certification (2 PfG 2750/09.20)

    Fully inherits all EN50618 H1Z2Z2-K test items, plus exclusive 100-day constant temperature water immersion aging test with DC voltage loaded; insulation & sheath keep tensile strength ≥7.0 N/mm², elongation ≥200% without bubbling, cracking or delamination. Ordinary PV1-F cables cannot pass this hydrolysis test.

  • ✅ Anti-Corrosion Tinned Class 5 Flexible Copper Conductor

    Multi-strand tinned copper prevents oxidation under long-term water vapor & salt fog, stable low resistance to reduce power loss; ultra-flexible for complex floating bracket routing, minimum bending radius 6× cable OD.

  • ✅ Custom Modified Hydrolysis-Resistant XLPO Double Cross-Linked Compound

    Proprietary AD8-grade sheath insulation formula with hydrolysis inhibitor, anti-mold masterbatch & reinforced UV shielding; water absorption rate below 0.1%, withstand continuous lake/reservoir water soaking.

  • ✅ Full LSZH Low Smoke Zero Halogen Fire Safety

    Meets IEC 60332-1 single cable flame retardant standard; low toxic smoke emission during fire, ideal for densely arranged floating PV stations near water sources.

  • ✅ Full Global Certifications for Global Project Bidding

    TÜV 2 PfG 2750/09.20, EN50618, IEC62930, UL4703, CE, CPR, RETIE; recognized in EU, Southeast Asia, Middle East, Africa & Latin America floating PV tender projects.

  • ✅ Wide Cross-Section Range & Stable Bulk Supply

    Available 1.5mm² ~ 35mm² red/black standard colors; factory mass production capacity supports bulk orders ≥10,000m, stable delivery cycle 7–15 working days.

  • ✅ 25-Year Service Life Warranty

    Specially optimized for high humidity, high UV, long-term water contact environments; far longer service span than common rooftop PV cables.

2. Product Structure

  1. Conductor: Class 5 tinned soft copper, IEC 60228 standard

  2. Insulation Layer: Modified irradiation cross-linked XLPO (AD8 hydrolysis resistant grade)

  3. Outer Sheath: Double cross-linked waterproof LSZH XLPO sheath (AD8 dedicated compound)

3. Complete Technical Specifications

Basic Electrical & Environmental Parameters

表格

Item

Standard Data

Rated Voltage

DC 1500V

AC Withstand Test Voltage

6.5kV, 50Hz, 5min

Continuous Working Temp

-40℃ ~ +90℃

Max Conductor Temp (Long-Term)

120℃

Short Circuit Withstand Temp

250℃, 5 seconds

Minimum Bending Radius

6 × cable outer diameter

Flame Retardant Standard

IEC 60332-1-2

Waterproof Grade

AD8 (TÜV 2 PfG 2750/09.20 hydrolysis certification)

Service Life

≥25 years under standard floating PV operation

Color Options

Standard Red / Black; custom colors for bulk orders

Available Cross-Section Sizes (mm²)

1.5, 2.5, 4, 6, 10, 16, 25, 35

4. Application Scenarios (Target Global Project Buyers)

  1. Core Scenario: Inland Lake & Reservoir Floating PV Power Plants

    Mandatory AD8 grade cable required by most EPC bidding documents, long-term contact with freshwater without insulation failure.

  2. Coastal Humid & Salt Fog Distributed PV

    Tinned copper + anti-salt fog sheath avoid conductor oxidation and sheath chalking.

  3. Tropical High-Humidity PV Projects (Philippines, Southeast Asia, Central America)

    Anti-mold & anti-hydrolysis formula resist year-round rain and high humidity.

  4. Direct Buried Underground PV Wiring

    No full conduit required, resist soil moisture, acid & alkali corrosion to cut construction cost.

  5. Industrial Sewage Tank, Freshwater Pool Top PV Installations

    Stable performance under persistent water vapor erosion.

Note: For offshore saltwater floating PV stations, choose our upgraded 2 PfG 2962 certified marine solar cable instead.

5. Wholesale & Order Information (MOQ Highlight Block)

Minimum Order Quantity

  • Standard MOQ: 10,000 meters per specification

  • Mixed cross-section bulk order acceptable for total quantity ≥10,000m

  • Sample support: Small test reels available, sample cost refundable after formal bulk order over MOQ

Bulk Order Terms

  1. Production Lead Time: 7–15 working days after deposit confirmation

  2. Packaging: Standard wooden reels (1000m / 2000m per reel), export fumigation-free wooden spools

  3. Shipping Port: FOB factory / FOB Ningbo / FOB Shanghai negotiable

  4. Customization Support: Custom cable printing, special length cutting, OEM brand printing for bulk orders over MOQ

  5. Payment Terms: T/T, L/C at sight

6. Certification Comparison: AD8 Cable vs Ordinary PV1-F Cable

表格

Item

Our AD8 Floating Cable (2 PfG 2750/09.20)

Common PV1-F Rooftop Cable (Only EN50618)

Long-Term Water Immersion Test

100 days 50℃ energized hydrolysis passed

Only 60min short-term water spray test

Sheath Compound

Modified AD8 anti-hydrolysis XLPO

General standard XLPE/XLPO without hydrolysis additive

Conductor

Tinned copper (anti-water oxidation)

Bare copper

Applicable Scene

Floating PV, coastal, buried, tropical humid PV

Dry rooftop, ground-mounted with full conduit

Service Life in Water Environment

25 years stable

3–5 years aging, leakage & ground fault risk

Project Bidding Requirement

Meet floating PV tender standard

Disqualified for water-surface PV projects

7. Frequently Asked Questions (FAQ for Featured Snippet Capture)

Q1: What does AD8 grade mean on solar cables?

A: AD8 is the industry abbreviation for the 100-day 50℃ energized warm water hydrolysis test defined by TÜV Rheinland specification 2 PfG 2750/09.20, representing permanent underwater service qualification for floating PV cables.

Q2: Can I use AD8 cable for regular rooftop solar systems?

A: Yes, AD8 cable fully covers all performance of standard EN50618 PV1-F wires with upgraded waterproof & anti-corrosion performance. It is a premium upgrade choice, though higher raw material cost makes it uneconomical for purely dry rooftop projects.

Q3: What is the MOQ for bulk AD8 solar cable orders?

A: Our minimum order quantity is 10,000 meters per size. Mixed cross-section orders are allowed as long as the total order length reaches 10,000 meters. Small sample reels can be provided for pre-order testing.

Q4: Is this AD8 cable suitable for sea/ocean saltwater floating PV?

A: Not recommended for offshore saltwater scenarios. Saltwater floating projects require our higher-grade cable certified to TÜV 2 PfG 2962/12.23 with extra long-term salt fog & marine microorganism resistance tests.

Q5: What certifications are provided for project bidding?

A: Full set of test reports & certification certificates including TÜV 2 PfG 2750/09.20, EN50618, IEC62930, UL4703, CE, CPR, RETIE, fully compliant with global PV tender standards.

solar cable manufacturer

Hualan Technology was founded in 2020, is a collection of solar accessories production, sales, research and development and service as one of the high-tech enterprises. At present, the business covers the production and sales of solar photovoltaic cables, photovoltaic cable connectors.

Related Products

CHAT US
CONTACT US
CONTACT
Scan code to add WhatsApp
CALL US
TOP